Brand Name : Eltek

Model Number : 241123.130

Certification : CE

Place of Origin : China

MOQ : 1

Price : 320USD

Payment Terms : T/T

Supply Ability : 200pcs/month

Delivery Time : 1 week

Packaging Details : Original Packed by Carton

Brand : Eltek

Part number : 241123.130

Country of Origin : China

Contact Now

Eltek Rectiverter 230V1500VA 110V1200W 241123.130

Rectifier & Inverter in one box

  • Built on HE technology from the Flatpack2 HE rectifier family the Rectiverter 230/1500 110/1200 provides backed up power for 230 VAC loads with minimum losses and footprint
  • It is a 3 port device capable of charging the 110V battery and simultaneously provides power for the AC and DC loads. During mains outage the Rectiverter feeds AC loads using energy stored in the battery.

Rectiverter 230V1500VA 110V1200W 241123.130
Models / ordering information 230/1500
110/1200
230/1500
110/1200
230/1500
110/0
115/750
110/600
115/750
110/0
115/750
110/0
Part number 241123.130 241123.131 241123.132 241123.130L 241123.131L 241123.132L
AC OUTPUT DATA
Voltage (default) / (adjustable range) 230 VAC / 200 - 241 VAC 115 VAC / 100 - 128 VAC
Frequency (default inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive), 94-106Hz6)
Power maximum (continuous / overload (<15s) ) 1200 W (1500 VA) / 2000 VA 600 W (750 VA) / 1000 VA
Load sharing ±5% of active power from 10 to 100% load
Current maximum (continuous / overload (<15s) ) 6.5 ARMS / 8.7 ARMS
Current (maximum) Quick trip (20ms) 32 A (6 x nominal)
THD < 1.5 % at resistive load
Protection Fuse in L, Hot pluggable, Varistor
DC OUTPUT DATA
Voltage (default) / (adjustable range) 122.5 VDC / 97 - 145 VDC
Power (maximum @nominal input) 1200 W 1) 150 W 0 W 2) 600 W 1) 75 W 0 W 2)
Current (maximum @VOUT ≤ 108 VDC) 11.11 A 1) 1.38 A - 5.55 A 1) 0.69 A -
Hold up time, maximum output power >10ms; VOUT > 95 VDC (only in rectifier mode)
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple < 500 mVPP , 30 MHz bandwidth
Protection Short circuit proof, Over voltage shutdown, Reversed polarity, ORing FET and Fuse
INPUT DATA
AC Mains Input Voltage (range / LV disconnect) 185 - 275 VAC / 170 VAC 95 - 140 VAC / 85 VAC
AC Current (maximum) 11.5 ARMS 9.1 ARMS 3) 8.2 ARMS 3) 11.3 ARMS 10.1 ARMS 3) 9.2 ARMS 3)
Frequency (default: sync range) 47-53 & 57-63 Hz 47-53 & 57-63 Hz
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD > 0.99 at 70% load or more / < 3.5%
AC Input Protection Fuse in L and N, Hot pluggable, Varistor
DC Voltage nominal / extended range4) 102 - 145 VDC / 90 - 102 VDC
DC Current (maximum) 12.5 A / 18 A during overload (15s) 6.3 A / 9 A during overload (15s)
OTHER SPECIFICATION
Efficiency >96% (mains mode), >95% (inverter mode) >93% (mains mode), >92% (inverter mode)
Isolation 3.85 kVDC - ACIN/OUT to PE, 3.55 kVDC - ACIN/OUT to DC, 4.25 kVDC - ACIN/OUT to CAN/SYNC, 1.75 kVDC -DC to PE, 3.5 kVDC - DC to CAN/SYNC
Alarms: Red LED
Alarm relay [NO max 75 VDC / 100 mA]
Low and high mains input voltage shutdown, High and low temperature shutdown, Rectiverter Failure,
Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure, Sync bus
lost and Sync fail
Warnings: Yellow LED Rectiverter in power de-rate mode or in power or current limit mode on DC or AC port, Remote output
current limit activated, Loss of CAN communication with controller
Normal operation: Green LED AC output and/or DC output on and ok
MTBF (Telcordia SR-332 Iss.I method III (a)) 260 000 hours (@ Tambient : 25 °C)
Operating temperature -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
Temperature de-rating above 55°C (131°F) 1200W to 480W @ 75°C (167°F) for each, AC and DC, outputs (total power 2000W to 800W)
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC/EN 62040-1:2008+A1:2013
UL 60950-1:2014, UL1778:2014, CSA C22.2 No. 107.3-14
EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, IEC 61000-6-5:2015
EN 62040-2:2006 (C1 emissions, C2/C3 immunity), FCC CFR 47 Part 15
EN50121 -2:2017+A1:2019, -4:2016+A1:2019, -5:2017+A1:20195)
Environment EU 2015/863 (RoHS) & 2012/19/EU (WEEE) / ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per
IEC 62040-5-3:2016 clause 4.3, must be advised

Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130


Product Tags:

241123.130 Eltek Rectiverter

      

Eltek Rectiverter 230V 1500VA

      

110V 1200W Eltek Rectiverter

      
Quality Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130 for sale

Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Guoguang Xingda Technology Co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)